Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 135
Filtrar
1.
J Inflamm Res ; 17: 581-589, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38318245

RESUMO

Purpose: Infection is the most common complication after left ventricular assist device (LVAD) implantation. The immune status of LVAD patients is relevant for the incidence and severity of infection, but it is unknown if there is a predisposing immune status prior to LVAD implantation that contributes to an increased risk for infection in the post-implant period. We analyzed the pre-LVAD immune status in patients with infection within 3 months after LVAD implantation in comparison to infection-free patients. Patients and Methods: Fifty-four consecutive LVAD patients were included in this study. According to their infectious history in the first 3 months after LVAD implantation, these patients were grouped into an infection (n=23) and an infection-free group (n=31). Pre-LVAD blood samples were obtained for flow cytometric analysis of immunological parameters including B cells, subsets of T, dendritic and natural killer cells. Patient-specific, clinical and laboratory data were recorded. Results: Blood count analysis prior to LVAD implantation showed comparable counts of erythrocytes (p=0.19), platelets (p=0.33) and leukocytes (p=0.50) between patients with infection and infection-free patients in the post-implant period. Patients with infection in the first 3 months after LVAD implantation had lower concentrations of lymphocytes (p=0.02). Forty percent of the patients with infection showed more often pre-LVAD neutrophil-to-lymphocyte ratios (NLR) >7 than patients without infection in the first 3 months after LVAD implantation (14%, p=0.05). Patients with infection already had lower percentages of CD3+ T cells (p=0.03), CD19+ B cells (p<0.01), BDCA2+ pDCs (p=0.03) and BDCA4+ plasmacytoid DCs (pDCs) (p=0.05) prior to LVAD implantation than infection-free patients. Conclusion: Our results demonstrated that patients with infection in the early post-implant period showed lower concentrations of lymphocytes, especially of CD3+ T cells and CD19+ B cells, decreased percentages of BDCA2+ and BDCA4+ pDCs, and had more often NLRs >7 indicating moderate-to-severe inflammation. Thus, we identified specific immunological changes pre-LVAD that could help to identify patients at risk for infection in the early post-implant period.

2.
Eur Heart J ; 45(8): 613-625, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38036414

RESUMO

BACKGROUND AND AIMS: HeartMate 3 (HM3) is a fully magnetically levitated continuous flow left ventricular assist device, which received CE marking in 2015. The ELEVATE Registry was initiated to collect real-world outcomes in patients treated with HM3 post-CE Mark approval. METHODS: A total of 540 subjects implanted at 26 centres between March 2015 and February 2017 were included in this registry. Of these, 463 received the device as a primary implant (primary implant cohort, PIC), 19 as a pump exchange (pump exchange cohort), and in 58 patients, only anonymized survival data were collected (anonymized cohort, AC). Patients in the PIC contributed to the baseline demographics, survival, adverse events, quality of life (QoL) (EuroQoL-5 Dimensions-5 Levels visual analogue scale), and functional capacity (6 min walk distance) assessments, while patients in the AC contributed only to survival. RESULTS: Primary implant cohort patients had a mean age of 56 years and were predominantly male (89%) with 48% ischaemic aetiology. The majority of subjects was designated bridge to transplant (66%) and had INTERMACS Profiles 1-3 (70%). At baseline, the subjects had poor functional capacity (104 ± 140 m) and impaired QoL (35 ± 19 points). The overall survival rate of the PIC was 63.3% and survival free of stroke was 58.1% at 5 years. Significant improvements in functional capacity and QoL were observed and maintained for 5 years (301 ± 131 m and 64 ± 20 points, respectively). CONCLUSIONS: Real-world data from the ELEVATE registry demonstrate an overall survival rate for primary implants of 63.3%. In the PIC, reductions in adverse events for patients in the extended follow-up and improved QoL and functional capacity were observed at 5 years in this patient population with advanced heart failure.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Coração Auxiliar/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Estudos Prospectivos , Sistema de Registros
3.
Front Immunol ; 14: 1256725, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37885885

RESUMO

Purpose: Infection is a common complication following left ventricular assist device (LVAD) implantation. Patients with obesity are particularly at risk due to their high percentage of adipose tissue and the resulting chronic inflammatory state and resulting immunological changes. This study investigated changes of immunological parameters in relation to body mass index (BMI) during the first year after LVAD implantation. Methods: Blood samples were obtained prior to LVAD implantation and at 3 (1st FU), 6 (2nd FU) and 12 mo (3rd FU) after LVAD implantation. Patients were divided into three groups (normal weight: BMI of 18.5-24.9 kg/m2; n=12; pre-obesity: 25.0-29.9 kg/m2; n=15; obesity: ≥ 30.0 kg/m2; n=17) based on their BMI at the time of LVAD implantation. Flow cytometric analyses for CD4+ and CD8+ T cells, regulatory T cells (Tregs), B cells as well as dendritic cells (DCs) were performed. Results: After LVAD implantation, obese patients (0.51 ± 0.20%) showed a higher proportion of overall DCs than normal-weight (0.28 ± 0.10%) and pre-obese patients (0.32 ± 0.11%, p<0.01) at 3rd FU. The proportion of BDCA3+ myeloid DCs was lower in obese patients (64.3 ± 26.5%) compared to normal-weight patients (82.7 ± 10.0%, pnormal-weight vs. obesity=0.05) at 2nd FU after LVAD implantation. The analysis of BDCA4+ plasmacytoid DCs revealed a reduced proportion in pre-obese (21.1 ± 9.8%, pnormal-weight vs. pre-obesity=0.01) and obese patients (23.7 ± 10.6%, pnormal-weight vs. obesity=0.05) compared to normal-weight patients (33.1 ± 8.2%) in the 1st FU. T cell analysis showed that CD4+ T cells of obese patients (62.4 ± 9.0%) significantly increased in comparison to pre-obese patients (52.7 ± 10.0%, ppre-obesity vs. obesity=0.05) and CD8+ T cells were lower in obese patients (31.8 ± 8.5%) than in normal-weight patients (42.4 ± 14.2%; pnormal-weight vs. obesity=0.04) at the 3rd FU. Furthermore, we observed significantly reduced proportions of Tregs in pre-obese patients compared to normal-weight and obese patients at 2nd FU (p=0.02) and 3rd FU (p=0.01) after LVAD implantation. Conclusion: This study reported changes of the innate and adaptive immune system of pre-obese and obese compared to normal-weight patients one year after LVAD implantation. DCs and their subsets, CD8+ T cells and Tregs were affected immune cell populations that indicate immunological changes which might increase the incidence of postoperative infection.


Assuntos
Coração Auxiliar , Humanos , Índice de Massa Corporal , Coração Auxiliar/efeitos adversos , Linfócitos T CD8-Positivos , Estudos Retrospectivos , Obesidade/complicações
4.
Life (Basel) ; 13(10)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37895427

RESUMO

Mechanical circulatory support has proven effective in managing postcardiotomy cardiogenic shock by stabilizing patients' hemodynamics and ensuring adequate organ perfusion. Among the available device modalities, the combination of extracorporeal life support and a microaxial flow pump for left ventricular unloading has emerged as a valuable tool in the surgical armamentarium. In this publication, we provide recommendations for the application and weaning of temporary mechanical circulatory support in cardiogenic shock patients, derived from a consensus among leading cardiac centers in German-speaking countries.

5.
Artigo em Inglês | MEDLINE | ID: mdl-37689237

RESUMO

OBJECTIVES: The Durable Mechanical Circulatory Support System After Extracorporeal Life Support registry is a multicenter registry of patients who were bridged from extracorporeal life support to a durable mechanical circulatory support system. Although numerous studies have highlighted the favorable outcomes after implantation of the HeartMate 3 (Abbott), the objective of our study is to examine the outcomes of patients who received HeartMate 3 support after extracorporeal life support. METHODS: Data of patients undergoing HeartMate 3 implantation from January 2016 to April 2022 at 14 centers were collected and evaluated. Inclusion criteria were patients with extracorporeal life support before HeartMate 3 implantation. The outcome was reported and compared with patients receiving other types of pumps. RESULTS: A total of 337 patients were bridged to durable mechanical circulatory support system after extracorporeal life support in the study period. Of those patients, 140 were supported with the HeartMate 3. The other types of pumps included 170 HeartWare HVADs (Medtronic) (86%), 14 HeartMate II devices (7%), and 13 (7%) other pumps (7%). Major postoperative complications included right heart failure requiring temporary right ventricular assist device in 60 patients (47%). Significantly lower postoperative stroke (16% vs 28%, P = .01) and pump thrombosis (3% vs 8%, P = .02) rates were observed in the patients receiving the HeartMate 3. The 30-day, 1-year, and 3-year survivals in patients receiving the HeartMate 3 were 87%, 73%, and 65%, respectively. CONCLUSIONS: In this critically ill patient population, the survivals of patients who were transitioned to the HeartMate 3 are deemed acceptable and superior to those observed when extracorporeal life support was bridged to other types of durable mechanical circulatory support systems.

6.
J Patient Rep Outcomes ; 7(1): 86, 2023 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-37615830

RESUMO

BACKGROUND: The guidelines for mechanical circulatory support of the International Society for Heart and Lung Transplantation do not recommend the routine replacement or repair of the mitral valve at the time point of left ventricular assist device (LVAD) implantation. We investigated different parameters of health status including exercise capacity, anxiety and depression after LVAD implantation in patients with different preoperative grades of mitral regurgitation (MR). METHODS: A single-center analysis of health status was performed including 45 patients with HeartMate 3 (HM 3) implantation using the 12-items Short Form Health Survey (SF-12) and the Hospital Anxiety and Depression Score (HADS) questionnaires. The study groups were classified according to echocardiographically defined preoperative grade of MR. The group without severe MR comprised 33 patients; the group with severe MR comprised 12 patients. RESULTS: Demographic and preclinical characteristics as well as LVAD complications such as thrombosis and bleeding events were comparable between LVAD patients with severe and not severe MR (p > 0.05). Severe MR resolved in all patients after LVAD implantation and improved to moderate, mild or no MR in both groups in a period ranging from 6 months until 2 years. The analyses of SF-12 questionnaire revealed that the physical (p = 0.44) and mental health (p = 0.64) was comparable. The grade of anxiety (p = 0.34) and depression (p = 0.44) was comparable between the groups. Exercise capacity measured by the 6 min walk test correlated positively with the SF-12-determined physical health (p < 0.01, r = 0.518) and negatively with the HADS anxiety (p = 0.01, r = -0.399) and depression (p < 0.01, r = -0.570) scores. CONCLUSIONS: Our data showed that the health status is comparable in HM 3 patients with different preoperative MR severities in the post-LVAD period. Preoperative severe MR resolves in the majority of patients early after LVAD implantation and is not associated with concomitant mitral valve repair or replacement at the time of LVAD implantation.


Assuntos
Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Nível de Saúde , Ansiedade , Transtornos de Ansiedade , Valva Mitral
7.
Ann Thorac Surg ; 116(5): 1079-1089, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37414384

RESUMO

BACKGROUND: Postcardiotomy venoarterial extracorporeal membrane oxygenation (VA ECMO) is characterized by discrepancies between weaning and survival-to-discharge rates. This study analyzes the differences between postcardiotomy VA ECMO patients who survived, died on ECMO, or died after ECMO weaning. Causes of death and variables associated with mortality at different time points are investigated. METHODS: The retrospective, multicenter, observational Postcardiotomy Extracorporeal Life Support Study (PELS) includes adults requiring postcardiotomy VA ECMO between 2000 and 2020. Variables associated with on-ECMO mortality and postweaning mortality were modeled using mixed Cox proportional hazards, including random effects for center and year. RESULTS: In 2058 patients (men, 59%; median age, 65 years; interquartile range [IQR], 55-72 years), weaning rate was 62.7%, and survival to discharge was 39.6%. Patients who died (n = 1244) included 754 on-ECMO deaths (36.6%; median support time, 79 hours; IQR, 24-192 hours), and 476 postweaning deaths (23.1%; median support time, 146 hours; IQR, 96-235.5 hours). Multiorgan (n = 431 of 1158 [37.2%]) and persistent heart failure (n = 423 of 1158 [36.5%]) were the main causes of death, followed by bleeding (n = 56 of 754 [7.4%]) for on-ECMO mortality and sepsis (n = 61 of 401 [15.4%]) for postweaning mortality. On-ECMO death was associated with emergency surgery, preoperative cardiac arrest, cardiogenic shock, right ventricular failure, cardiopulmonary bypass time, and ECMO implantation timing. Diabetes, postoperative bleeding, cardiac arrest, bowel ischemia, acute kidney injury, and septic shock were associated with postweaning mortality. CONCLUSIONS: A discrepancy exists between weaning and discharge rate in postcardiotomy ECMO. Deaths occurred during ECMO support in 36.6% of patients, mostly associated with unstable preoperative hemodynamics. Another 23.1% of patients died after weaning in association with severe complications. This underscores the importance of postweaning care for postcardiotomy VA ECMO patients.

8.
J Am Heart Assoc ; 12(14): e029609, 2023 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-37421269

RESUMO

Background Extracorporeal membrane oxygenation (ECMO) has been increasingly used for postcardiotomy cardiogenic shock, but without a concomitant reduction in observed in-hospital mortality. Long-term outcomes are unknown. This study describes patients' characteristics, in-hospital outcome, and 10-year survival after postcardiotomy ECMO. Variables associated with in-hospital and postdischarge mortality are investigated and reported. Methods and Results The retrospective international multicenter observational PELS-1 (Postcardiotomy Extracorporeal Life Support) study includes data on adults requiring ECMO for postcardiotomy cardiogenic shock between 2000 and 2020 from 34 centers. Variables associated with mortality were estimated preoperatively, intraoperatively, during ECMO, and after the occurrence of any complications, and then analyzed at different time points during a patient's clinical course, through mixed Cox proportional hazards models containing fixed and random effects. Follow-up was established by institutional chart review or contacting patients. This analysis included 2058 patients (59% were men; median [interquartile range] age, 65.0 [55.0-72.0] years). In-hospital mortality was 60.5%. Independent variables associated with in-hospital mortality were age (hazard ratio [HR], 1.02 [95% CI, 1.01-1.02]) and preoperative cardiac arrest (HR, 1.41 [95% CI, 1.15-1.73]). In the subgroup of hospital survivors, the overall 1-, 2-, 5-, and 10-year survival rates were 89.5% (95% CI, 87.0%-92.0%), 85.4% (95% CI, 82.5%-88.3%), 76.4% (95% CI, 72.5%-80.5%), and 65.9% (95% CI, 60.3%-72.0%), respectively. Variables associated with postdischarge mortality included older age, atrial fibrillation, emergency surgery, type of surgery, postoperative acute kidney injury, and postoperative septic shock. Conclusions In adults, in-hospital mortality after postcardiotomy ECMO remains high; however, two-thirds of those who are discharged from hospital survive up to 10 years. Patient selection, intraoperative decisions, and ECMO management remain key variables associated with survival in this cohort. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT03857217.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Masculino , Humanos , Adulto , Idoso , Feminino , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , Assistência ao Convalescente , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Alta do Paciente , Mortalidade Hospitalar
9.
Struct Heart ; 7(1): 100098, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37275309

RESUMO

Reoperative valve surgery is being performed with increasing frequency in the last decades. This is mainly due to the increasing use of bioprosthetic valves, a growing population of patients presenting with prosthetic valve endocarditis, and an ageing population. Reoperative valve surgery has been historically associated with poorer outcomes than primary valve surgery. However, continuous advancements in modern cardiac surgery techniques and perioperative care have led to considerable improvement in postoperative outcomes. This review outlines considerations for reoperative heart valve surgery including preoperative assessment, perioperative management, and technical surgical aspects to maximize the chances of successful outcomes in this challenging patient population.

11.
Obes Facts ; 16(4): 364-373, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37232004

RESUMO

INTRODUCTION: Infections are a major problem after left ventricular assist device (LVAD) implantation that affects morbidity, mortality, and the quality of life. Obesity often increases the risk for infection. In the cohort of LVAD patients, it is unknown if obesity affects the immunological parameters involved in viral defense. Therefore, this study investigated whether overweight or obesity affects immunological parameters such as CD8+ T cells and natural killer (NK) cells. METHODS: Immune cell subsets of CD8+ T cells and NK cells were compared between normal-weight (BMI 18.5-24.9 kg/m2, n = 17), pre-obese (BMI 25.0-29.9 kg/m2, n = 24), and obese (BMI ≥30 kg/m2, n = 27) patients. Cell subsets and cytokine serum levels were quantified prior to LVAD implantation and at 3, 6, and 12 months after LVAD implantation. RESULTS: At the end of the first postoperative year, obese patients (31.8% ± 2.1%) had a lower proportion of CD8+ T cells than normal-weight patients (42.4% ± 4.1%; p = 0.04), and the percentage of CD8+ T cells was negatively correlated with BMI (p = 0.03; r = -0.329). The proportion of circulating NK cells increased after LVAD implantation patients in normal-weight (p = 0.01) and obese patients (p < 0.01). Patients with pre-obesity showed a delayed increase (p < 0.01) 12 months after LVAD implantation. Further, obese patients showed an increase in the percentage of CD57+ NK cells after 6 and 12 months (p = 0.01) of treatment, higher proportions of CD56bright NK cells (p = 0.01), and lower proportions of CD56dim/neg NK cells (p = 0.03) 3 months after LVAD implantation than normal-weight patients. The proportion of CD56bright NK cells positively correlated with BMI (p < 0.01, r = 0.403) 1 year after LVAD implantation. CONCLUSIONS: This study documented that obesity affects CD8+ T cells and subsets of NK cells in patients with LVAD in the first year after LVAD implantation. Lower proportions of CD8+ T cells and CD56dim/neg NK cells and higher proportion of CD56bright NK cells were detected in obese but not in pre-obese and normal-weight LVAD patients during the first year after LVAD implantation. The induced immunological imbalance and phenotypic changes of T and NK cells may influence viral and bacterial immunoreactivity.


Assuntos
Insuficiência Cardíaca , Qualidade de Vida , Humanos , Obesidade/complicações , Obesidade/terapia , Índice de Massa Corporal , Estudos Retrospectivos
12.
J Thorac Cardiovasc Surg ; 166(6): 1670-1682.e33, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37201778

RESUMO

OBJECTIVES: Postcardiotomy extracorporeal membrane oxygenation (ECMO) can be initiated intraoperatively or postoperatively based on indications, settings, patient profile, and conditions. The topic of implantation timing only recently gained attention from the clinical community. We compare patient characteristics as well as in-hospital and long-term survival between intraoperative and postoperative ECMO. METHODS: The retrospective, multicenter, observational Postcardiotomy Extracorporeal Life Support (PELS-1) study includes adults who required ECMO due to postcardiotomy shock between 2000 and 2020. We compared patients who received ECMO in the operating theater (intraoperative) with those in the intensive care unit (postoperative) on in-hospital and postdischarge outcomes. RESULTS: We studied 2003 patients (women: 41.1%; median age: 65 years; interquartile range [IQR], 55.0-72.0). Intraoperative ECMO patients (n = 1287) compared with postoperative ECMO patients (n = 716) had worse preoperative risk profiles. Cardiogenic shock (45.3%), right ventricular failure (15.9%), and cardiac arrest (14.3%) were the main indications for postoperative ECMO initiation, with cannulation occurring after (median) 1 day (IQR, 1-3 days). Compared with intraoperative application, patients who received postoperative ECMO showed more complications, cardiac reoperations (intraoperative: 19.7%; postoperative: 24.8%, P = .011), percutaneous coronary interventions (intraoperative: 1.8%; postoperative: 3.6%, P = .026), and had greater in-hospital mortality (intraoperative: 57.5%; postoperative: 64.5%, P = .002). Among hospital survivors, ECMO duration was shorter after intraoperative ECMO (median, 104; IQR, 67.8-164.2 hours) compared with postoperative ECMO (median, 139.7; IQR, 95.8-192 hours, P < .001), whereas postdischarge long-term survival was similar between the 2 groups (P = .86). CONCLUSIONS: Intraoperative and postoperative ECMO implantations are associated with different patient characteristics and outcomes, with greater complications and in-hospital mortality after postoperative ECMO. Strategies to identify the optimal location and timing of postcardiotomy ECMO in relation to specific patient characteristics are warranted to optimize in-hospital outcomes.


Assuntos
Oxigenação por Membrana Extracorpórea , Adulto , Humanos , Feminino , Idoso , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , Assistência ao Convalescente , Alta do Paciente , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia
13.
Front Cardiovasc Med ; 10: 974527, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37252124

RESUMO

Objectives: Several studies have shown the potential advantage of less-invasive surgery (LIS) for left ventricular assist device (LVAD) implantation. This study aims to determine the impact of LIS on stroke and pump thrombosis events after LVAD implantation. Methods: Between January 2015 and March 2021, 335 consecutive patients underwent LVAD implantation using either conventional sternotomy (CS) or the LIS technique. Patient characteristics was prospectively collected. All patients were followed up until October 2021. Logistic multivariate regression and propensity-matched analyses were performed to account for confounding factors. Results: A total of 242 patients (F = 32; 13.0%) underwent LVAD implantation with CS and 93 patients (F = 8; 8.6%) with the LIS approach. Propensity matching generated two groups, including 98 patients in the CS group and 67 in the LIS group. Intensive care unit stay for the LIS group patients was significantly shorter than that for the CS group patients [2 (IQR: 2-5) days vs. 4 (IQR: 2-12) days, p < 0.01]. There were no significant differences in the incidence of stroke events (14% in CS vs. 16% in the LIS group; p = 0.6) or in pump thrombosis (6.1% in CS vs. 7.5% in the LIS group; p = 0.8) between the groups. The hospital mortality rate in the matched cohort was significantly lower in the LIS group (7.5% vs. 19%; p = 0.03). However, the 1-year mortality rate showed no significant difference between both groups (24.5% in CS and 17.9% in LIS; p = 0.35). Conclusions: The LIS approach for LVAD implantation is a safe procedure with potential advantage in the early postoperative period. However, the LIS approach remains comparable to the sternotomy approach in terms of postoperative stroke, pump thrombosis, and outcome.

15.
Eur J Cardiothorac Surg ; 63(6)2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37027228

RESUMO

OBJECTIVE: During a transcatheter aortic valve implant (TAVI) procedure, intraprocedural complications that are manageable only by conversion to emergency open-heart surgery (E-OHS) occasionally occur. Contemporary data on the incidence and outcome of TAVI patients undergoing E-OHS are scarce. This study aimed to evaluate early and midterm outcomes following E-OHS of patients undergoing TAVI in a large tertiary care centre with immediate surgical backup availability for all TAVI procedures over a 15-year period. METHODS: Data from all patients undergoing transfemoral TAVI between 2006 and 2020 at the Heart Centre Leipzig were analysed. The study time was divided into 3 periods: 2006-2010 (P1), 2011-2015 (P2) and 2016-2020 (P3). Patients were grouped according to their surgical risk (high risk: EuroSCORE II ≥ 6%; low/intermediate risk: EuroSCORE II <6%). Primary outcomes were intraprocedural and in-hospital death and 1-year survival. RESULTS: During the study period, a total of 6903 patients underwent transfemoral TAVI. Among them, 74 (1.1%) required E-OHS [high risk, n = 66 (89.2%); low/intermediate risk, n = 8 (10.8%)]. The rate of patients requiring E-OHS was 3.5% (20/577 patients), 1.8% (35/1967 patients) and 0.4% (19/4359 patients) in study periods P1 to P3, respectively (P < 0.001). The proportion of patients who had E-OHS who were low/intermediate risk increased considerably over time (P1:0%; P28.6%; P3:26.3%; P = 0.077). Intraprocedural deaths occurred in 10 patients (13.5%), all of whom were high-risk. In-hospital mortality was 62.1% in high-risk patients and 12.5% in low/intermediate risk patients (P = 0.007). One-year survival was 37.8% in all patients undergoing E-OHS, 31.8% in high-risk patients and 87.5% in low/intermediate risk patients (log-rank P = 0.002). CONCLUSIONS: In-hospital and 1-year survival rates following E-OHS are higher in low/intermediate risk than in high-risk patients undergoing TAVI. An on-site cardiac surgical department with immediately available E-OHS capabilities is an important component of the TAVI team.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Centros de Atenção Terciária , Incidência , Mortalidade Hospitalar , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Implante de Prótese de Valva Cardíaca/métodos
16.
Ann Thorac Surg ; 116(1): 147-154, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37015310

RESUMO

BACKGROUND: Obesity is an important health problem in cardiac surgery and among patients requiring postcardiotomy venoarterial extracorporeal membrane oxygenation (V-A ECMO). Still, whether these patients are at risk for unfavorable outcomes after postcardiotomy V-A ECMO remains unclear. The current study evaluated the association between body mass index (BMI) and in-hospital outcomes in this setting. METHODS: The Post-cardiotomy Extracorporeal Life Support (PELS-1) study is an international, multicenter study. Patients requiring postcardiotomy V-A ECMO in 36 centers from 16 countries between 2000 and 2020 were included. Patients were divided in 6 BMI categories (underweight, normal weight, overweight, class I, class II, and class III obesity) according to international recommendations. Primary outcome was in-hospital mortality, and secondary outcomes included major adverse events. Mixed logistic regression models were applied to evaluate associations between BMI and mortality. RESULTS: The study cohort included 2046 patients (median age, 65 years; 838 women [41.0%]). In-hospital mortality was 60.3%, without statistically significant differences among BMI classes for in-hospital mortality (P = .225) or major adverse events (P = .126). The crude association between BMI and in-hospital mortality was not statistically significant after adjustment for comorbidities and intraoperative variables (class I: odds ratio [OR], 1.21; 95% CI, 0.88-1.65; class II: OR, 1.45; 95% CI, 0.86-2.45; class III: OR, 1.43; 95% CI, 0.62-3.33), which was confirmed in multiple sensitivity analyses. CONCLUSIONS: BMI is not associated to in-hospital outcomes after adjustment for confounders in patients undergoing postcardiotomy V-A ECMO. Therefore, BMI itself should not be incorporated in the risk stratification for postcardiotomy V-A ECMO.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Oxigenação por Membrana Extracorpórea , Humanos , Feminino , Idoso , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Mortalidade Hospitalar , Oxigenação por Membrana Extracorpórea/efeitos adversos , Estudos Retrospectivos , Obesidade/complicações , Choque Cardiogênico/etiologia
17.
Int J Mol Sci ; 24(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36982712

RESUMO

Non-surgical bleeding (NSB) remains the most critical complication in patients under left ventricular assist device (LVAD) support. It is well known that blood exposed to high shear stress results in platelet dysfunction. Compared to patients without NSB, decreased surface expression of platelet receptor GPIbα was observed in LVAD patients with NSB. In this study, we aimed to compare the expression level of glycoprotein (GP)Ib-IX-V platelet receptor complex in HeartMate 3 (HM 3) patients with and without bleeding complications to investigate the alterations of the platelet transcriptomic profile on platelet damage and increased bleeding risk. Blood samples were obtained from HM 3 patients with NSB (bleeder group, n = 27) and without NSB (non-bleeder group, n = 55). The bleeder group was further divided into patients with early NSB (bleeder ≤ 3 mo, n = 19) and patients with late NSB (bleeder > 3 mo, n = 8). The mRNA and protein expression of GPIbα, GPIX and GPV were quantified for each patient. Non-bleeder, bleeder ≤ 3 mo and bleeder > 3 mo were comparable regarding the mRNA expression of GPIbα, GPIX and GPV (p > 0.05). The protein analysis revealed a significantly reduced expression level of the main receptor subunit GPIbα in bleeders ≤ 3 mo (p = 0.04). We suggest that the observed reduction of platelet receptor GPIbα protein expression in patients who experienced their first bleeding event within 3 months after LVAD implantation may influence platelet physiology. The alterations of functional GPIbα potentially reduce the platelet adhesion capacities, which may lead to an impaired hemostatic process and the elevated propensity of bleeding in HM 3 patients.


Assuntos
Plaquetas , Complexo Glicoproteico GPIb-IX de Plaquetas , Humanos , Plaquetas/metabolismo , Membrana Celular/metabolismo , Complexo Glicoproteico GPIb-IX de Plaquetas/genética , Complexo Glicoproteico GPIb-IX de Plaquetas/metabolismo , Hemorragia/genética , Adesividade Plaquetária , RNA Mensageiro/metabolismo
18.
J Artif Organs ; 26(2): 156-159, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35951178

RESUMO

The optimal surgical approach in patients with pectus excavatum (PEx) who need cardiac surgery remains uncertain. The challenge is even greater, if it is already foreseeable that the patient will be needed further procedure in the next future. We describe a novel sternotomy-sparing approach for minimal-invasive biventricular assist device (BiVAD) implantation in a patient with an acute heart failure (HF) due to dilated cardiomyopathy and severe PEx. Moreover, alternative approaches for ventricular assist device (VAD) implantation and timing of the repair of PEx will be discussed.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tórax em Funil , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Tórax em Funil/complicações , Tórax em Funil/cirurgia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Esternotomia/métodos , Estudos Retrospectivos , Resultado do Tratamento
19.
Ann Thorac Surg ; 116(6): 1186-1193, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35697115

RESUMO

BACKGROUND: Guidelines on the management of aortic aneurysm disease do not account for sex differences regarding surgical procedures on the proximal aorta, although faster aneurysm growth, increased rupture risk, and higher postoperative mortality have been found in women. We therefore analyzed outcome differences between men and women receiving operations on the proximal aorta. METHODS: A total of 1773 patients underwent nonemergency surgical procedures on the aortic valve (AV) and proximal aorta at our institution between 2000 and 2018. Of these, 772 patients (21.8% women) received a Bentall procedure, 349 (20.3% women) had AV-sparing root replacement, and 652 (31.1% women) underwent AV and supracommissural ascending aorta replacement. Primary outcomes were in-hospital mortality and midterm survival. RESULTS: When assessing sex-related differences within the entire group of patients that received an operation on the proximal aorta, women were found to be older, had a lower body mass index, and were smokers less often. Despite shorter procedural times, median ventilation times and intensive care unit length of stay were longer in women. In-house mortality was also higher in women (3.6% vs 0.9%, P < .001). Multivariable logistic regression revealed age (odds ratio [OR], 1.8; 95% CI, 1.4-2.3 per 5 years added; P < .001), female sex (OR, 2.6; 95% CI, 1.2-5.8; P = .02), and urgent surgery (OR, 3.1; 95% CI, 1.2-7.3; P = .01) as independent risk factors for in-house death. Midterm survival was lower for women in the entire cohort (P = .02) and particularly within the Bentall subgroup (P = .004). CONCLUSIONS: Female sex is an independent risk factor for operative mortality in patients undergoing proximal aortic surgery but is currently not addressed in guidelines. More research should focus on etiology and prevention of these worse outcomes in female patients.


Assuntos
Aneurisma Aórtico , Doenças da Aorta , Humanos , Feminino , Masculino , Caracteres Sexuais , Resultado do Tratamento , Estudos Retrospectivos , Aneurisma Aórtico/cirurgia , Aorta/cirurgia , Valva Aórtica/cirurgia
20.
ASAIO J ; 69(2): 145-150, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35438667

RESUMO

Stroke is one of the leading complications following durable mechanical circulatory support (MCS) implantation. The aim of this multicenter study was to investigate stroke complications in patients requiring durable MCS following extracorporeal life support (ECLS). Data of 11 high volume MCS centers were collected and evaluated to identify patients who underwent durable MCS implantation after ECLS support between January 2010 and August 2018. The primary outcome was stroke following durable MCS implantation. Univariate and multivariate logistic regression analyses were performed to determine predictors of stroke. Overall, 531 patients met the inclusion criteria. Only patients who were supported with continuous flow pumps were included in this study accounting for 495 patients (median age 54 years old [interquartile range 47-60]). A total of 136 patients (27%) developed postoperative stroke on device during the follow-up (48% ischemic and 52% hemorrhagic) after a median durable MCS support of 320 [32-1,000] days, accounting for 0.17 events per patient-year. Of 133 patients with known date of stroke, a total of 47 (10%) developed stroke during the first 30 days (64% ischemic and 36% hemorrhagic), and 86 patients developed stroke after 30 days (38% ischemic and 62% hemorrhagic) of durable MCS support (late stroke). Survival rate was significantly lower in patients with hemorrhagic stroke ( p = 0.00091). Stroke appears to be a common complication in patients transitioned to durable MCS support after ECLS. Hemorrhagic stroke is a more common type of late stroke and is associated with inferior outcomes.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral Hemorrágico , Humanos , Pessoa de Meia-Idade , Oxigenação por Membrana Extracorpórea/efeitos adversos , Acidente Vascular Cerebral Hemorrágico/etiologia , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento , Insuficiência Cardíaca/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA